IAM Adjustments
When calculating the heat output of a collector, the IAM performance adjustment factor (K) should be included in the efficiency formula.
![]()
The key difference to that formula presented on performance basic of this section is the inclusion of the factor K in front of the y-intercept value. The K value can also include the longitudinal IAM factor, thus taking into consideration the installed angle of the collector too. This is achieved by simply multiplying the two IAM factors to provide a complete IAM value.
If we continue with the example from performance basic
x = (50-25)/800 = 0.03125
Now enter all the values into the efficiency formula:
h(x) = 1.37*0.717 - (1.52*0.03125) - (0.0085*800*0.031252)
h(x) = 0.98 - 0.0475 - 0.0066 = 0.926
The performance value calculated with the above formula can then be used to calculate total heat output:
Heat Output = Performance x Insolation x Collector Surface Area
Example:
Performance @ 40o angle= 92.6%
Insolation = 800 Watts/m2
Absorber Surface Area = 2.4m2
Heat Output = 0.926 x 800 x 2.4 = 1777Watts
So the collector will provide 1.77 kW of heat output.
How can the performance reach 92.6%? Remember that the efficiency variables and therefore this performance value is is expressed for absorber area, if using gross surface area the % efficiency value would be almost half this, but given the larger surface area if using gross, the heat output is the same. It is possible therefore for the % value to exceed 100% - it does not mean that more heat is being produced that the sun is providing, but rather due to reflection off neighbouring tubes etc, the amount of light the absorber is exposed to is greater than when the collector perpendicular to the sunlight rays (midday).
Simplifying IAM Adjustment Calculations
To complete a simple single day calculation for the purpose of comparing collector performance, an average IAM value can be use, along with an average Watt/m2 value. Although this won't give a completely accurate indication of the heat output for the day, it allows a comparison between the two collector to be made.
As the majority of useful solar radiation falls during the middle 6-7 hours of the day, an average of the IAM values during this period can be used. If 1 hour corresponds to 15o then 7 hours corresponds to 50o either side of midday. The average cosine adjusted IAM for the SunSurfs solar collector for this period is 1.2, and a flat plate collector is 0.97. These factors can therefore be used in the performance formula. See the additional links more detail.