Installation Basics
When choosing a solar collector, selecting the correct size is important. To find out what size collector you need please click here. Once you have determined what size collector suits your needs, the next question is where to install it.
Deciding the Direction and Angle of Installation
. 
- Melbourne, Australia has a latitude of 37o South - the collector should therefore face north at a 37o angle.
- London, UK has a latitude of 51o North - the collector should therefore face south at a 51o angle.
Seasonal Changes in Heat Output
How to prevent excessive summer heat output
If you do not have an additional means of using the excess heat, then adjusting the angle of the collector can help to reduce summer heat output. As can be seen by the diagram above, the sun is low in the sky during the winter and high in the summer. Solar smart house designs will take advantage of this by having big North or South (depending on your location) facing windows allowing maximum absorption of winter sun, with large eves or veranda to block out the summer sun.
By increasing the vertical angle of the collector by about 20o more the location's latitude (ie. 60o instead of 40o), greater winter performance will be experienced. This is because the collector is "facing" the sun (perpendicular - longitudinal angle). Due to the higher location of the sun in the sky during the summer, the collector will be around 40o from perpendicular and as such heat output will be reduced as the collector is not fully "facing" the sun. This simple solution alone can reduce peak summer output considerably, thus reducing problems associated with excessive summer heat production. Click here to see image of passive solar tracking.

The above photo shows an ideal example of an installation angle that optimises winter, spring and autumn heat output, while minimising summer output. The high angle not only maximises expose to the direct winter sun, but also allows the sunlight reflected off the snow to be absorbed. In the summer when the sun is high overhead the exposed surface area is small, especially with the overhanging roof which would partially shade the collector. In areas without snow fall (and a latitude range of 30-40o) an angle lower than that shown above would be suitable.
Please note: For the SunSurfs solar water heater, optimal heat pipe performance is achieved in the angle range of 20-70o. Although your locations may have a latitude of less than 20o, this basic installation guideline should be adhered to. Horizontal angles of +/- 5o are acceptable and may be appropriate if the manifold needs to be drainable (end port models only).